Commutateur de relais populaire T90 20 30A Charge utilisée en moto
Précautions concernant le relais de puissance : 1. Suggestions de couvercle anti-poussière en plastique Nous recommandon
Description
Informations de base
Modèle NON. | WJ115 |
Caractéristiques de protection | Relais scellé |
Principe d'action | Type électromagnétique |
Taille | Miniature |
Taper | Relais de paramètre électrique |
Nom du produit | Commutateur de relais populaire T90 20 30A Charge |
Numéro d'article | Wj115 |
Courant maximum | 30A |
Arrangement de contact | 1A,1b,1c/ Non, Nc, Transfert |
Capacité de contact | 28 VCC, 250 VCA |
Tension de bobine | 3~48VDC |
Couleur | Noir |
Matériel de contact | Agsno2 |
Lester | 30g |
Méthode de montage | PCB |
Forfait transport | 200 pièces dans 1 carton |
spécification | 27.3*32.2*20.2mm |
Marque déposée | étoile wanjia |
Origine | Zhejiang, Chine |
Code SH | 8536411000 |
Capacité de production | 5, 000, 000.00/ an |
Description du produit
spécification | Courant maximum | 30A (10A/20A) | |||
Arrangement | 1A / 1C | ||||
Matériel de contact | Alliage d'argent | ||||
Résistance de contact (par chute de tension 6V 1A) | Max.30mΩ | ||||
Capacité nominale de commutation Charge résistive | 30A NC 10A 240VAC240VAC NC 20A 24VDC | ||||
Tension de commutation max. | 250 VCA | ||||
Max. Puissance de commutation | 7200VA NC : 2400VA 7200VA NON : 4800VA | ||||
Durée de vie mécanique (à 120 cpm) | 1*107 | ||||
Durée de vie électrique (à 20 cpm) | 2*104 | ||||
Temps de fonctionnement | Max.15ms | ||||
Temps de libération | Max.10ms | ||||
Résistance diélectrique | Contact ouvert | ≥2500 VCA | |||
Bobine et Contact | ≥2500 VCA | ||||
La resistance d'isolement | ≥1000mΩ | ||||
Humidité de fonctionnement | 45~85% | ||||
Température ambiante | -40ºC~70ºC | ||||
Résistance aux vibrations | Fonctionnel | 10 ~ 55 Hz à double amplitude de 1,5 mm | |||
Destruction | 10 ~ 55 Hz à double amplitude de 1,5 mm | ||||
Résistance au choc | Fonctionnel | Min.10G | |||
Destruction | Au moins 100 G |
Précautions du relais de puissance :
1.Suggestions of Plastic Anti-dust Cover We highly recommend cover : (1)When the ambient humidity is ≥ 60% (for example refrigerator or some country like Indian), the metal parts of relay will be weakened in different degrees due to long-term exposure to the outdoors in terms of electrical conductivity and service life. (2)When the dust density is high in the environment, all kinds of impurities carried in the dust (such as gravel), if gravel is embedded between contacts. Firstly, it will affect the normal opening and closing of contacts;Secondly, part of the silicon oxide can be used as a semiconductor to conduct electricity, and then the relay's on and off will fail if no anti-dust cover. (3)When corrosive gases are serious in the environment, it will accelerate the metal aging, greatly affecting the service life of electrical relays. * When none of the above situations exists, the plastic anti-dust cover is not necessary due to extra cost. 2.Suggestions of Contacts (1)We should pay attention to prevent contact movement, adhesion, abnormal consumption, increase of contact resistance and other fault phenomena while using. (2)The material of power relay can be AgCd010,AgSn08,AgSnOlnO etc.Wanjia star brand relay adopted AgSnO2 with high quality & stable performance. (3)The mechanical service life and electrical service life can be main factor too * In a word, good device need good relay to low the repairing rates and improve the endurance.